Siemtcoat® EM5503 is an advanced two-component emulsion-based system, specifically formulated to deliver superior performance in both paper and PET film coating applications.
Siemtcoat® EM5503
Emulsion Silicone Release Coating for Paper & PET Film
Siemtcoat® EM5503 is an advanced two-component emulsion-based system, specifically formulated to deliver superior performance in both paper and PET film coating applications.
General
A two-component emulsion-based system, specially designed for food paper, PET, ect. substrate coatings.
We recommend the following formulas:
Siemtcoat® EM5503 (Base Polymer)
Siemtcoat® EM5509 (Catalyst)
Applications
Siemtcoat® EM5503, a safe and environmentally friendly emulsion-based silicone release coating,can be widely applied to paper, PET film, etc. Its applications span across the following fields:
Advantages
Siemtcoat® EM5503 is suitable for various coating machines, especially suitable for direct coating on paper machines or solvent-based release agent coating equipment for coating processing, thereby conveniently replacing solvent-based products, with the following characteristics:
Properties
|
Appearance |
Milky Liquid |
|
Silicone Active Ingredient(%) |
40 |
|
Typical Viscosity(mm2/s ,25℃) |
200 |
|
Density (g/cm3) |
0.99 |
Processing
When applying Siemtcoat® EM5503 into the Siemtcoat system, please strictly adhere to the following mixing procedure:
For detailed formulation guidance, feel free to contact us.
Precautions: When opening the lid of the Emulsion main polymer, observe whether there is any swelling or gas buildup.
If no gas expansion is observed, it is recommended to wear anti-static clothing, discharge static electricity before operation, open the cover with a metal tool, and then slowly open the vent valve using an explosion-proof drum opener. After opening the vent valve, leave the area and wait for a few minutes to allow residual hydrogen gas inside the drum to escape. Then proceed with the sampling operation.
In case of barrel expansion, first move the barrel to an open outdoor area, perform static electricity elimination on the barrel shell, and then follow the previous operational procedure.
The detail information could consult us for the formulation advice.
Bath life
The bath life of all Siemtcoat systems depends on formulation, equipment, mixing process, temperature, and environment. Siemtcoat® EM5503 only does not alter its original bath life, typically lasting about 6 hours at 40℃.
Release force
Release force performance depends on multiple factors.
We measure release force using different substrates and adhesives to define its characteristics. While the standard release force measure could use standard tape to measure.
Typical release force performance:
Tesa Tape 7475 (23℃): 5 to 15 g/25mm (0.3 m/min peeling speed)
Curing
The curing results of the Siemtcoat system depend primarily on the formulation, substrate quality, curing temperature, and oven efficiency. We obtained the following results:
| Substrate | Temperature | Curing Time |
| 50μPET | 130℃ |
<12s |
(Curing time is defined as the minimum curing duration without any smear, rub-off, or migration of the release coating layer.)
Operational Precautions
Siemtcoat® EM5503 releases hydrogen gas slowly. The rate of hydrogen release will accelerate under the action of a catalyst, or if it is contaminated by alkaline substances, heavy metals or their compounds. Do not place the emulsion in a container without ventilation openings.
Keep Siemtcoat® EM5503 away from sparks and open flames, and ensure good ventilation in the use area. Avoid contact with skin and eyes. To prevent pressure accumulation during hydrogen release, it is recommended to ventilate the containers holding the base emulsion regularly. In this way, no pressure will build up even if the container's ventilation openings are blocked.
Pre-use Inspection & Barrel Opening Operation
First check the barrel for bulging before any operation.
If no bulging is observed: Wear anti-static clothing and discharge static electricity prior to operation; open the cover with metal tools, then slowly open the breather valve with an explosion-proof barrel opener. Step away from the barrel immediately after opening the valve and wait a few minutes for the small amount of residual hydrogen inside to escape, then conduct sampling operations.
If bulging occurs: First move the barrel to an open outdoor area, eliminate static electricity on the barrel’s outer surface, then follow the above barrel opening procedure.
Static Electricity Prevention
Static electricity may be generated when SI-H products flow through pipelines, are discharged from pipelines or fall freely. Appropriate measures shall be taken to eliminate static electricity and avoid spark generation.
Equipment Cleaning
When cleaning equipment containing Siemtcoat® EM5503 emulsion, use surfactants and detergents with caution. These agents are alkaline and may induce hydrogen gas generation.
Package
|
Siemtcoat® EM5503 |
950kg/IBC Drum or180kg/Iron Drum |
|
Siemtcoat® EM5509 |
20kg/Plastic Drum or1kg/Plastic Bottle |
Shelf Life
Siemtcoat® EM5503 should be stored in a closed container at +10°C to +30°C temperature.
Siemtcoat standard shelf-life is 12 months.
Safety
Please refer to the Siemtcoat® EM5503/EM5509 MSDS.
Remark
Emulsion type silicones should be agitated thoroughly before use.
Emulsion type silicones may freeze at low temperatures, so users in colder regions should take special care with regard to storage.
Emulsion type silicones should be storage in a closed container at 10°C to +30°C temperature.